Plan Content
Requirements
Plans should include the following specifications:
-
The entire layout of the floor
plan.
• The plan should be accurately
drawn to a minimum scale of ¼ inch = 1 foot. This allows for ease in reading
plans. Plans provided should be a maximum of 11 by 14 inches.
• Entrances, exits, loading/unloading areas, docks and interior doors.
-
All doors and windows leading to
the outside must be protected against the entry of insects and rodents.
Windows should be closed and tight fitting. If they are open, a proper
screen must be in place (16 mesh to 1 inch screen). Doors shall be solid,
self-closing, and tight fitting. External emergency exit doors that are
restricted from non-emergency use do not need to have a self-closing device
installed. If a solid door is left open for ventilation, a proper screen
door must be in place. The screen door must have a self-closing device
installed and the screen must be 16 mesh to 1 inch. • All restroom doors must
be self closing.
-
Complete finish schedules for
each room. • Ceilings must be constructed with materials that are smooth, durable,
non-absorbable and easily cleanable in food preparation areas, food storage
areas, warewashing areas, walk-in refrigeration and freezer units, restrooms,
wait stations (if more than just beverages are dispensed), and in areas subject
to flushing or spray cleaning methods. • Studs, joists and rafters may not be exposed in areas subject to moisture.• The ceiling surfaces in a bar area or waitress area in which the only open
foods prepared are beverages and the only warewashing taking place is of glasses
and small utensils will not be required to be non-absorbent. The surfaces,
however, must be smooth and easily cleanable. • The ceiling surfaces of the employee restrooms of food establishments that
only sell prepackaged, non-potentially hazardous foods will not be required to
be non-absorbent. The surfaces, however, must be smooth and easily cleanable. • Walls must be constructed of materials that are smooth, durable, non-absorbent
and easily cleanable in food preparation areas, food storage areas, warewashing
areas, walk-in refrigeration and freezer units, employee restrooms and in areas
subject to moisture. • Floors must be constructed of materials that are smooth, non-absorbent,
durable and easily cleanable in food preparation areas, food storage areas,
warewashing areas, walk-in refrigeration and freezer units, restrooms and areas
subject to moisture.
-
Complete plumbing schedule. • Source of water supply and method of sewage disposal designated.
• A properly designed dipperwell must be provided for frozen desserts, if
applicable.
• A three-compartment sink with adequate drain boards must be provided for the
manual washing, rinsing and sanitizing of kitchenware; and/or
• Adequate mechanical warewashing facilities with properly designed drain boards
or moveable dish tables provided. Readable data plate, pressure gauge,
temperature gauge and sanitizer level indicator provided as required.
• Grease traps if used; shall be located to be easily accessible for cleaning.
• Provision of hot and cold water (with adequate pressure) at all fixtures and
equipment that use water.
• Installation of exposed pipes, lines and conduits so as not to obstruct or
prevent cleaning of floors, walls and ceilings is required.
• Floor drains provided where floors are subject to flushing or spray cleaning
methods. • Provide properly designed faucets on hand washing lavatories providing
tempered water by means of a mixing valve or combination faucet.
• Sufficient number of and conveniently located hand washing lavatories for use
by employees in food preparation, warewashing areas and bar areas with no
physical barriers between the hand sink and work stations. Note: The Food and
Drug Administration and the Conference for Food Protection suggest that a hand
washing sink be located within 25 feet of all food activity/workstations.
• Sufficient number of and conveniently located toilet facilities provided for
employee use.
• An adequate and properly located utility (mop) sink or curbed cleaning
facility must be provided.
• Properly designed devices installed at all fixtures and equipment to protect
against backflow and backsiphonage; food preparation sinks, ice bins, dipper
wells and dish machines.
-
Complete lighting/electrical
schedule. • At least 70 foot-candles of lighting must be provided on all food preparation
surfaces, equipment and warewashing work levels.
• At least 20 foot-candles of lighting must be provided (at a distance of 30
inches above the floor) walk in refrigeration/freezer units, utensil and
equipment storage areas, lavatory and toilet areas.
• Light bulbs must be shielded, coated or other wise shatter-resistant in areas
where there is exposed food, clean equipment, utensils, linens or unwrapped
single service and single use items. Note: Infrared/heat lamps must be protected
against breakage by a shield surrounding and extending beyond the bulb so that
only the face of the bulb is exposed.
-
Complete equipment schedule. • Food equipment must be designed and constructed to be durable. Materials used
in the construction of food contact surfaces may not allow the migration of
deleterious substances or impart colors, odors or tastes to food and shall be
safe, durable, corrosion resistant and non-absorbent. They must be finished to
have a smooth, easily cleanable surface and be resistant to chipping, pitting,
crazing, scratching, scoring, distortion and decomposition. Only hard maple or
an equivalently hard, closed grained wood may be used as a food contact surface.
Any used equipment must meet all requirements of 410-IAC 7-24.
• All equipment must be properly placed. Food service equipment may not be
located in the following locations : locker rooms, toilet rooms, garbage rooms,
mechanical rooms (when contamination is likely), under sewer lines that are not
shielded to intercept potential drips, under any leaking water lines
(condensation included), under open stair wells or under other sources of
contamination. Equipment that is fixed (not easily moveable), must be placed so
that it is spaced to allow access for cleaning along the sides, behind, under
and above, or sealed to adjoining equipment and walls to prevent food debris or
other contamination from collecting in the gaps.
• Non-food contact surfaces of equipment that are exposed to splash, spillage or
other food soiling or that require frequent cleaning shall be constructed of
corrosion-resistant, non-absorbent and smooth material.
• Use properly designed display cases and food shields where required.
-
Complete ventilation schedule. • Properly designed and approved ventilation for food service equipment (cooking
equipment and hot water sanitizing dish machines) as required by the Fire and
Building Departments.
• Mechanical exhaust ventilation must be provided in all restrooms.
-
Site plan (plot plan). • Exterior walking and driving surfaces graded to drain.
• Exterior walking and driving surfaces constructed of concrete, asphalt or
gravel or other materials that have been effectively treated to minimize dust,
facilitate maintenance and prevent muddy conditions.
• Outdoor dumpster pads constructed of concrete or asphalt and are sloped to
drain.
-
Miscellaneous plan content
requirements. • Designation of adequate facilities for the storage of employees’ personal
items.
• Designation of adequate facilities for the storage of maintenance and cleaning
tools.
• Adequate and properly located laundry facilities if used.
• Describe where raw meats will be processed.
• A signed menu must be submitted
|